| Technical Data |
Sprinter 150/150M |
Sprinter 250M |
| Height accuracies |
Standard devation height measurement per 1 km double run (ISO 17123-2) |
Standard devation height measurement per 1 km double run (ISO 17123-2) |
| −Electronic measurement* |
1.5 mm |
1.0/0.7* mm |
| −Optical measurement |
With standard aluminum E-scale/Numeral staff: 2.5 mm |
With standard aluminum E-scale/Numeral staff: 2.5 mm |
| −Single staff reading |
Standard Deviation: 0.6 mm (electronic) and 1.2 mm (optical) at 30m |
Standard Deviation: 0.6 mm (electronic) and 1.2 mm (optical) at 30m |
| Distance accuracies |
Standard deviation distance measurement 10 mm for D ≤ 10 m and (Distance in m x 0.001) for D > 10 m |
Standard deviation distance measurement 10 mm for D ≤ 10 m and (Distance in m x 0.001) for D > 10 m |
| Range |
2 - 100 m (electronic) |
2 - 100 m (electronic) |
| Measuring modes |
Single and Tracking |
Single and Tracking |
| Time for single measurement |
<3 sec |
<3 sec |
| Compensator |
Magnet damped pendulum compensator (range +/- 10min) |
Magnet damped pendulum compensator (range +/- 10min) |
| Telescope |
Magnification (optical) 24x |
Magnification (optical) 24x |
| Data storage |
up to 1'000 points (only 150M) |
up to 1'000 points |
| Environmental conditions |
IP55 |
IP55 |
| Power supply |
AA dry cells (4 x LR6/AA/AM3 1.5 V) |
AA dry cells (4 x LR6/AA/AM3 1.5 V) |
| Weight |
<2.5 kg |
<2.5 kg |