Favorable/average measuring conditions:
- Materials with good reflecting characteristics, meaning they reflect the laser beam in a divergent
(not mirrored!) manner
- Laser dot is brighter than the ambient light
- Betrieb Operating within the allowable temperature range (-10° + 50° C)
Unfavorable measuring conditions:
- Highly reflective surfaces
- Highly absorbing surfaces, such as wet or dark surfaces
- Operating at the limits of the allowable temperature range
- Not waiting for temperature calibration
- Very intensive ambient light
- Shimmering
- For optical and safety reasons, do not measure against colorless liquids (water) or glass